INNOVATIVE TECHNOLOGY EVALUATION REPORT, SEDIMENT SAMPLING TECHNOLOGY, ART'S MANUFACTURING, SPLIT CORE SAMPLER FOR SUBMERGED SEDIMENTS

On this page:

  • Overview
  • Downloads

The Split Core Sampler for Submerged Sediments (Split Core Sampler) designed and fabricated by Arts Manufacturing & Supply, Inc., was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the samplers ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Split Core Sampler and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Split Core Sampler performed as well as or better than the reference samplers. Based on visual observations, both the Split Core Sampler and reference samplers collected partially compressed samples of consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved for both consolidated and unconsolidated sediment samples collected by the Split Core Sampler and reference samplers. No sampler was able to collect samples in the deep depth interval (4 to 11 feet below sediment surface). The average sampling time was less for the Split Core Sampler than for the reference samplers. Sampling costs for the Split Core Sampler were 8 percent greater than those for the Hand Corer and 95 percent less than those for the Vibrocorer.

Impact/Purpose

The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

Citation

Topudurti, K., E. Monschein, AND A. Bajorat. INNOVATIVE TECHNOLOGY EVALUATION REPORT, SEDIMENT SAMPLING TECHNOLOGY, ART'S MANUFACTURING, SPLIT CORE SAMPLER FOR SUBMERGED SEDIMENTS. U.S. Environmental Protection Agency, Washington, DC, EPA/600/R-01/009 (NTIS PB2003-106592), 2001.

Download(s)


Related Link(s)

  • SUPERFUND INNOVATIVE TECHNOLOGIES EVALUATION (SITE) PROGRAM FOR MONITORING AND CHARACTERIZATION TECHNOLOGIES
  • Dioxin Home
  • Learn about Dioxin
  • Common Sources of Exposure
  • Dioxin Databases, Methods, and Tools
  • Publications
  • Resources
Contact Us to ask a question, provide feedback, or report a problem.
Last updated on December 22, 2005
United States Environmental Protection Agency

Discover.

  • Accessibility Statement
  • Budget & Performance
  • Contracting
  • EPA www Web Snapshots
  • Grants
  • No FEAR Act Data
  • Privacy
  • Privacy and Security Notice

Connect.

  • Data
  • Inspector General
  • Jobs
  • Newsroom
  • Open Government
  • Regulations.gov
  • Subscribe
  • USA.gov
  • White House

Ask.

  • Contact EPA
  • EPA Disclaimers
  • Hotlines
  • FOIA Requests
  • Frequent Questions

Follow.