Electrical Aerosol Detector (EAD) Measurements At The St. Louis Supersite

On this page:

  • Overview
  • Downloads
The Model 3070A Electrical Aerosol Detector (EAD) measures a unique aerosol parameter called total aerosol length. Reported as mm/cm3, aerosol length can be thought of as a number concentration times average diameter, or simply as d1 weighting. This measurement falls between number concentration (d0) and surface area (d2). The EAD is a robust, easy-to-use, low-cost aerosol measurement instrument. It provides fast response and displays data in real time.

An EAD was operated for about two years at the St. Louis supersite. A second EAD was co-located for about 6 months. Information on precision, reliability and consistency will be discussed. Diurnal profiles of the EAD signal for several days, daily averages for several months, and monthly averages for the entire period will be reported.

Correlations of the EAD signal with SMPS measurements of DX for X from 0 to 3 will be reported. Reasons for the correlation being better for X around 1.5 instead of 1.0 will be discussed.

Earlier studies have suggested that the EAD signal is highly correlated with the calculated deposition of particle surface area to the lung. Correlation of the EAD signal with the calculated deposition of particle surface area for several breathing patterns will be presented. The possibility of using the EAD as an indicator of PM surface dose to the lung will be considered.

Citation

Han, H. S., S. Kaufman, J. Turner, W Wilson, AND D. Y. Pui. Electrical Aerosol Detector (EAD) Measurements At The St. Louis Supersite. Presented at AAAR PM Supersites Program and Related Studies International Specialty Conference, Atlanta, GA, February 07 - 11, 2005.

Download(s)

This download(s) is distributed solely for the purpose of pre-dissemination peer review under applicable information quality guidelines. It has not been formally disseminated by EPA. It does not represent and should not be construed to represent any Agency determination or policy.

  • Electrical Aerosol Detector (EAD) Measurements at the St. Louis Supersite (PDF)  (1  pp, 15.6 KB, about PDF)
  • Risk Assessment Home
  • About Risk Assessment
  • Risk Recent Additions
  • Human Health Risk Assessment
  • Ecological Risk Assessment
  • Risk Advanced Search
    • Risk Publications
  • Risk Assessment Guidance
  • Risk Tools and Databases
  • Superfund Risk Assessment
  • Where you live
Contact Us to ask a question, provide feedback, or report a problem.
Last updated on July 12, 2006
United States Environmental Protection Agency

Discover.

  • Accessibility Statement
  • Budget & Performance
  • Contracting
  • EPA www Web Snapshots
  • Grants
  • No FEAR Act Data
  • Privacy
  • Privacy and Security Notice

Connect.

  • Data
  • Inspector General
  • Jobs
  • Newsroom
  • Open Government
  • Regulations.gov
  • Subscribe
  • USA.gov
  • White House

Ask.

  • Contact EPA
  • EPA Disclaimers
  • Hotlines
  • FOIA Requests
  • Frequent Questions

Follow.